  • Fire Smoke Damper for Shaft Enclosure - HVAC R engineering
    If the roof assembly is not rated, then you need a fire damper at the OA duct penetration at the bottom of the rated shaft A SFD could be applied but a FD with the correct rating should meet your requirements
  • Firestopping Vertical Horizontal Penetrations
    The spread of fire can be restricted by dividing a building into separate compartments with fire-resistive walls and floors—increasing the availability of escape routes for occupants One globally applied principle for fire safety:
  • Enclosing Shafts to Reduce Fire Spread in Construction
    Shafts, such as elevator shafts and stairwells, can provide a path for fire and smoke to travel vertically between floors Enclosing these shafts helps contain the fire and limit its spread, providing more time for evacuation and firefighting efforts
  • Cheat Sheet Table: Where are Fire or Smoke Dampers Required?
    Fire and smoke dampers are essential for preventing the spread of fire and smoke through HVAC systems They are required in various locations, including penetrations of fire-rated walls, floors, ceilings, and shafts
  • CGC SHAFT WALL SYSTEMS - USG
    Walls that enclose elevator shafts, stairwells and other vertical shafts are the lifeline of a building Should a fire occur, firefighters control the use of elevators, leaving stairwells as the only means for occupant egress or rescue within the building
  • Excerpts from the Canadian National Building Code (NBC) - firestop
    "Standard Method of Fire Tests of Firestop Systems," with a pressure differential of 50Pa between the exposed and unexposed sides, with the higher pressure on the exposed side, and (b) the piping is not located in a vertical shaft 5 Combustible drain piping is permitted to penetrate a horizontal fire
  • Fire Stopping Service Penetrations in Buildings - The City of Calgary
    understanding the requirements for fire stopping penetrations through fire separations in buildings The guide primarily addresses issues in multi-family residential construction,
  • Conquest Flamebar Vertical Fire-stop - YouTube
    How to create a fire-stop between floors for a vertical shaft using Flamebar as the rated shaft In addition, how to take advantage of what many contractors